The 1991 edition of IS 2222 outlines the specifications regarding the size, quality, and physical properties required for burnt clay perforated bricks utilized in wall and partition construction. This standard is intended for producers, distributors, and engineering professionals to ensure these bricks meet prescribed benchmarks such as strength, moisture absorption, efflorescence resistance, and dimensional accuracy to guarantee their durability and functionality in building projects.
نظرة عامة
The 1991 edition of IS 2222 outlines the specifications regarding the size, quality, and physical properties required for burnt clay perforated bricks utilized in wall and partition construction. This standard is intended for producers, distributors, and engineering professionals to ensure these bricks meet prescribed benchmarks such as strength, moisture absorption, efflorescence resistance, and dimensional accuracy to guarantee their durability and functionality in building projects.
الجمهور
المحتويات
الهيكل
IS 2222: Scope & Core Specifications
| Dimension (mm) | Permissible Variation (mm) |
|---|---|
| 70, 90 | ±4 |
| 110, 190 | ±7 |
| 230 | ±10 |
This section ensures consistent brick sizing and quality assessment under IS 2222.
IS 2222:1991 - Associated Indian Standards (Annex A)
The standard references several crucial Indian Standards to support comprehensive compliance and understanding:
| IS Number | Description |
|---|---|
| IS 2248:1991 | Glossary of clay product terms for building uses (2nd revision) |
| IS Parts 1-4:1991 | Specifications for building bricks, Parts 1 to 4 (3rd edition) |
| IS 5454:1978 | Sampling methodology for clay |
| IS 3495 | Testing methods for burnt clay building bricks |
flowchart LR
A[IS 2222] --> B[IS 2248: Terminology]
A --> C[IS 5454: Sampling]
A --> D[IS 3495: Testing]
A --> E[IS Parts 1-4: Brick Specifications]
This framework ensures a thorough approach to quality and compliance.
IS 2222 - Definitions and Clarifications
Definitions: As per Clause 3.1, terms used are defined by IS 2248:1991 for burnt clay bricks. Refer for terms such as "Modular Brick" and "Overburnt Brick".
Rounding Off (Clause 4): Final measurement and testing data should be rounded in line with IS 2:1960, maintaining the significant figures as per specifications.
Dimensional Tolerances (Clause 5.2): Acceptable size deviations are:
| Dimension (mm) | Allowable Tolerance (mm) |
|---|---|
| 70, 90 | ±4 |
| 110, 190 | ±7 |
| 230 | ±10 |
| Brick Size (mm) | Allowed Variation (mm) |
|-----------------|-----------------------|
| 70, 90 | ±4 |
| 110, 190 | ±7 |
| 230 | ±10 |
Cross-reference IS 2248:1991 for comprehensive definitions.
IS 2222: Overview of Quality Requirements
Terminology: Refer to IS 2248:1991 for relevant terms.
Rounding Practices (Clause 4): Numerical figures must conform to rounding rules of IS 2:1960, retaining the prescribed number of significant digits.
Sampling and Acceptance (Clause 8.1): Sampling must follow procedures outlined in IS 5454:1978.
Minimum Thickness Parameters (Clause 6.4):
| Element | Minimum Thickness |
|---|---|
| Shell | 15 mm |
| Web | 10 mm |
flowchart TD
A[Product: Brick] --> B{Component Thickness}
B --> C[Shell ≥ 15 mm]
B --> D[Web ≥ 10 mm]
E[Testing] --> F[Rounding per IS 2:1960]
G[Sampling] --> H[IS 5454:1978 Compliance]
This assures brick manufacturing meets quality standards.
IS 2222 - Specifications on Dimensions and Tolerances
| Brick Type | Length (mm) | Width (mm) | Height (mm) |
|---|---|---|---|
| Modular | 190 | 90 | 90 |
| Non-modular | 230 | 110 | 70 |
| Dimension (mm) | Allowed Tolerance (± mm) |
|---|---|
| 70, 90 | 4 |
| 110, 190 | 7 |
| 230 | 10 |
Ensures dimensional precision and quality for strength and aesthetic uniformity in masonry.
IS 2222: Requirements for Brick Perforations
Perforation Area Ratio: The perforations must cover between 30% and 45% of the brick face area (Clause 6.1).
Size Limits for Perforations:
Maximum Area per Perforation: No individual perforation should exceed 500 mm² (Clause 6.3).
Distribution: Perforations should be evenly spread across the brick face (Clause 6.2).
| Parameter | Specification | Additional Notes |
|---|---|---|
| Perforation area ratio | 30% to 45% | Percentage of brick face |
| Max perforation area | ≤ 500 mm² | Per individual hole |
| Rectangular perforation | Short side < 20 mm | Longer side parallel to length |
| Circular perforation | Diameter < 25 mm | |
| Distribution | Uniform | Across entire brick surface |
graph LR
A[Brick Face] --> B[Rectangular Holes]
B --> C[Longer side aligned with brick length]
B --> D[Shorter side < 20 mm]
A --> E[Circular Holes]
E --> F[Diameter < 25 mm]
These criteria ensure bricks provide sufficient strength, ventilation, and insulation.
IS 2222: Summary of Physical Characteristics
Minimum Thickness Requirements:
Dimensional Tolerances (Clause 5.2):
| Size (mm) | Allowed Deviation (mm) |
|---|---|
| 70, 90 | ±4 |
| 110, 190 | ±7 |
| 230 | ±10 |
Rounding of Results: Testing values must be rounded following IS 2:1960 guidelines, maintaining the number of significant digits (Clause 7).
Terminology: Refer to IS 2248:1991 for relevant definitions (Clause 3.1).
flowchart TD
A{Brick Dimension} -->|70 or 90 mm| B[Tolerance ±4 mm]
A -->|110 or 190 mm| C[Tolerance ±7 mm]
A -->|230 mm| D[Tolerance ±10 mm]
B & C & D --> E[Verify Thickness]
E --> F[Shell ≥ 15 mm]
E --> G[Web ≥ 10 mm]
F & G --> H[Compliance with IS 2222]
IS 2222: Sampling Methods and Compliance Standards
Sampling Approach: Following Clause 8.1, sampling and acceptance procedures align with IS 5454:1978, which covers:
Compliance Requirements:
| Parameter | Reference Standard | Requirement/Limit |
|---|---|---|
| Sampling & Acceptance | IS 5454:1978 | Statistical sampling method |
| Maximum Warpage | IS 3495 Parts 1-4 (1991) | ≤ 3% average warpage |
| Rounding Off | IS 2:1960 | Same decimal places as specified |
flowchart TD
A[Sampling per IS 5454] --> B{Test Results}
B -->|Meets Criteria| C[Accept Batch]
B -->|Does Not Meet| D[Reject Batch]
C --> E[Report with Rounded Values]
D --> E
This framework guarantees consistent quality evaluation and reporting for bricks.
Key Directives:
Clause 9.1: Every brick must be imprinted with the manufacturer’s identifying mark or initials in an appropriate manner.
Clause 9.1.1: Bricks may optionally bear the BIS Standard Mark to indicate certification.
Rounding of Test Data: Test or analysis results need to be rounded as per IS 2:1960, retaining the original significant digits.
| IS Number | Title |
|---|---|
| 2248 | Glossary of terms for clay building products |
| 5454 | Clay sampling methodology |
| 3495 | Testing methods for burnt clay bricks |
flowchart TD
A[Brick Production] --> B[Mark with Manufacturer ID]
B --> C{Certified by BIS?}
C -- Yes --> D[Apply Standard Mark]
C -- No --> E[No Standard Mark]
D & E --> F[Bricks Ready for Distribution]
Summary: Manufacturer identification marking is mandatory, with the BIS Standard Mark applied if certification is obtained, supporting quality control and traceability.
الأسئلة المتكررة
As per IS 2222 (1991), the standard brick sizes and tolerances are:
| Brick Type | Length (mm) | Width (mm) | Height (mm) |
|---|---|---|---|
| Modular | 190 | 90 | 90 |
| Non-modular | 230 | 110 | 70 |
| Dimension (mm) | Tolerance (± mm) |
|---|---|
| 70, 90 | 4 |
| 110, 190 | 7 |
| 230 | 10 |
Each individual brick dimension must fall within these tolerance limits to ensure consistency and proper fit in masonry applications.
جارٍ تحميل المخطط…
According to IS 2222, the minimum average compressive strength for perforated burnt clay bricks must be at least 7 N/mm² measured on the net cross-sectional area (Clause 7.1). Additional stipulations include:
This ensures adequate structural performance alongside design requirements.
جارٍ تحميل المخطط…
Water absorption testing under IS 2222 (Clause 7.2) follows IS 3495 (Parts 1 to 4): 1991 procedures:
Immerse the brick in cold water for 24 hours.
Weigh the brick before and after immersion.
Calculate water absorption percentage using: [ \text{Water Absorption %} = \frac{\text{Wet weight} - \text{Dry weight}}{\text{Dry weight}} \times 100 ]
The maximum permissible water absorption is 20% by weight.
This test confirms the brick's resistance to moisture and durability.
جارٍ تحميل المخطط…
IS 2222 specifies the following for brick perforations:
These standards ensure the bricks combine lightness, thermal insulation, and structural integrity.
جارٍ تحميل المخطط…
According to IS 2222:
Marking facilitates quality assurance and helps users verify adherence to the standard. Marks should be clear but not compromise the brick’s structural integrity.
جارٍ تحميل المخطط…