IS 14856:2000 specifies requirements for Glass Fibre Reinforced Plastic (GRP) panel type door shutters intended for internal use, particularly in bathrooms, toilets, and kitchens. It covers materials, dimensions, manufacturing processes, mechanical and fire performance tests, and installation guidelines to ensure durable, maintenance-free, and fire-retardant doors suitable for residential and commercial interiors.
نظرة عامة
IS 14856:2000 specifies requirements for Glass Fibre Reinforced Plastic (GRP) panel type door shutters intended for internal use, particularly in bathrooms, toilets, and kitchens. It covers materials, dimensions, manufacturing processes, mechanical and fire performance tests, and installation guidelines to ensure durable, maintenance-free, and fire-retardant doors suitable for residential and commercial interiors.
الجمهور
المحتويات
الهيكل
IS 14856: Scope — Key Specifications & Formulas
| Door Designation | Width | Height (Standard / Finished Floor) |
|---|---|---|
| 8 DS 20 | 700 | 1905 (1945) |
| 9 DS 20 | 800 | 1905 (1945) |
| 12 DT 21 | 1100 | 2005 (2045) |
[ E = \frac{P L^3}{4 b d^3 D} ]
Where:
[ \text{Absorption} % = \frac{W_2 - W_1}{W_1} \times 100 ]
Where:
flowchart LR
A[Modular Door Opening] --> B[Calculate Overall Dimensions]
B --> C[Select Door Shutter Size]
C --> D
IS 14856 Key References, Formulas & Tables Summary
Elastic Modulus in Bending:
[
E = \frac{P L^3}{4 b d^3 D}
]
Where:
Where:
Where:
[ E = \frac{PL^3}{4bd^3D} ]
Where:
[ \text{Absorption coefficient (%)} = \frac{W_2 - W_1}{W_1} \times 100 ]
Where:
| Designation | Width (mm) | Height (mm) |
|---|---|---|
| 8 DS 20 | 700 | 1905 (1945) |
| 9 DS 20 | 800 | 1905 (1945) |
| 10 DS 20 | 900 | 1905 (1945) |
| 12 DT 20 | 1100 | 1905 (1945) |
IS 14856: Key Formulas and Specifications for Materials
Calculated from the initial linear portion of the load-deflection curve in a 3-point bending test.
[ E = \frac{P L^3}{4 b d^3 D} ]
[ \text{Absorption coefficient (%)} = \frac{W_2 - W_1}{W_1} \times 100 ]
[ TS = \frac{L_B}{A} ]
Specimens: Thickness ≥ 3 mm, tested at 27 ± 2°C, fracture time 30-90 s.
flowchart LR
A[Spec
IS 14856 - Composition and Additives: Key Points
[ E = \frac{PL^3}{4bd^3 D} ]
Where:
[ \text{Absorption} % = \frac{W_2 - W_1}{W_1} \times 100 ]
Where:
| Parameter | Limit/Condition |
|---|---|
| Fillers & Additives | ≤ 10% by weight of resin |
| Glass Content | Determined by furnace method |
| Elastic Modulus | Calculated by bending test formula |
| Water Absorption | Measured after 24 h immersion |
flowchart TD
A[Isophthalic Resin] --> B[Additives & Fillers ≤ 10%]
IS 14856: Key Construction & Design Specifications
| Designation | Width (mm) | Height (mm) |
|---|---|---|
| 8 DS 20 | 700 | 1905 (1945) |
| 8 DS 21 | 700 | 2005 (2045) |
| 9 DS 20 | 800 | 1905 (1945) |
| 9 DS 21 | 800 | 2005 (2045) |
| 10 DS 20 | 900 | 1905 (1945) |
| 10 DS 21 | 900 | 2005 (2045) |
| 12 DT 20 | 1100 | 1905 (1945) |
| 12 DT 21 | 1100 | 2005 (2045) |
[ E = \frac{P L^3}{4 b d^3 D} ]
Where:
[ \text{Absorption %} = \frac{W_2 - W_1}{W_1} \times 100 ]
IS 14856 - Sizes and Types of Door Shutters
| Designation | Width (mm) | Height (mm) (Finished Floor Level) |
|---|---|---|
| 8 DS 20 | 700 | 1,905 (1,945) |
| 8 DS 21 | 700 | 2,005 (2,045) |
| 9 DS 20 | 800 | 1,905 (1,945) |
| 9 DS 21 | 800 | 2,005 (2,045) |
| 10 DS 20 | 900 | 1,905 (1,945) |
| 10 DS 21 | 900 | 2,005 (2,045) |
| 12 DT 20 | 1,100 | 1,905 (1,945) |
| 12 DT 21 | 1,100 | 2,005 (2,045) |
| Component | Width (mm) | Thickness (mm) |
|---|---|---|
| Vertical stile, top & freeze rail | 90 ± 3 | 30 ± 1 or 35 ± 1 |
| Lock rail | 120 ± 3 | 30 ± 1 or 35 ± 1 |
| Bottom rail | 150 ± 3 | 30 ± 1 or 35 ± 1 |
IS 14856: Locations of Fittings and Accessories (Clause 8)
Hinges:
Other Fixtures:
| Door Designation | Width (mm) | Height (mm) |
|---|---|---|
| 8 DS 20 | 700 | 1905 (1945) |
| 8 DS 21 | 700 | 2005 (2045) |
| 9 DS 20 | 800 | 1905 (1945) |
| 9 DS 21 | 800 | 2005 (2045) |
| 10 DS 20 | 900 | 1905 (1945) |
| 10 DS 21 | 900 | 2005 (2045) |
| 12 DT 20 | 1100 | 1905 (1945) |
| 12 DT 21 | 1100 | 2005 (2045) |
| Parameter | Formula/Value |
|---|---|
| Overall Height | MH - 10 mm |
| Shutter Height | MH - 95 mm |
| Overall Width | MW - 10 mm |
| Shutter Width | MW - 100 mm |
Where:
flowchart TB
A[Door Shutter]
IS 14856: Surface Quality Requirements & Related Specifications
[ \text{Tensile Strength (TS)} = \frac{L_B}{A} ]
| Parameter | Unit | Description |
|---|---|---|
| (L_B) | N | Load at break |
| (A) | mm² | Original cross-sectional area |
| (TS) | MPa | Tensile strength |
| Test Type | Thickness (mm) | Specimen Count | Edge Distance (mm) | Surface Quality |
|---|---|---|---|---|
| Hardness | ≥ 1.5 | 5 | ≥ 3 | Buffed & polished |
| Tensile Strength | ≥ 3 | 5 | N/A | Smooth, no mechanical damage |
flowchart LR
A[Raw Material] --> B[Cut Specimens]
B --> C{Thickness}
C -->|≥1.5 mm| D[Hardness Test]
C -->|≥3 mm| E[Tensile Test]
D --> F[Buff & Polish Surface]
E --> F
F --> G[Testing]
G --> H[Calculate TS or Hardness]
Note: Follow IS 2:1960 for rounding off test results.
IS 14856 – Tests on Door Shutters (Summary of Key Requirements & Formulas)
| Test Type | Standard Part | Key Limits/Criteria |
|---|---|---|
| Dimensions & Squareness | Part 2 | ±5 mm size, ≤1 mm/500 mm squareness |
| Impact Indentation | Part 8 | 5 impacts both sides, no damage |
| Buckling | Part 9 | Residual deflection ≤5 mm, max deflection 50 mm |
flowchart LR
A[Door Shutter] --> B[Dimension & Squareness Test]
A --> C[Impact Indentation Test]
A --> D[Buckling Test]
B -->|Tolerance ±5 mm| E[Width & Height]
B -->|Deviation ≤1 mm/500 mm| F[Squareness]
C -->|5 impacts both sides| G[No permanent deformation]
D -->|Residual deflection ≤5 mm| H[No deterioration]
D -->|Initial deflection ≤50 mm| I[Deflection Limit]
This ensures door shutters meet durability and dimensional accuracy per IS 14856 & IS 4020.
IS 14856 - Marking: Key Specifications & Related Test Procedures
| Test | Specimen Details | Key Formula / Procedure |
|---|---|---|
| Tensile Strength (Annex D) | 5 specimens, thickness ≥ 3 mm, conditioned at 27±2°C | [ |
| TS = \frac{L_B}{A} | ||
| ] |
IS 14856 - BIS Certification Mark Key Points
| Test | Key Details | Formula / Method |
|---|---|---|
| Glass Content of Laminates (Annex B) | Use muffle furnace at 575 ± 25°C to burn resin, weigh residue | Follow heating/weighing cycles until constant weight |
| Elastic Modulus in Bending (Clause 1.5, Annex F) | 3-point bending test with span = 16 × thickness | |
| [ | ||
| E = \frac{PL^3}{4bd^3D} | ||
| ] | ||
| Where: |
| IS No. | Title |
|---|---|
| 4020 (Parts 1-16) | Door shutters - Methods of tests |
| 4021 | Timber door, window & ventilator frames |
| 4351 | Steel door frames |
| 6746 | Unsaturated polyester resin systems |
| 11320 | Glass fibre rovings for reinforcement |
| 11551 | Glass fibre chopped strand mat |
| 12406 | Medium density fibre board |
| 6523 | Precast reinforced concrete door/window frames |
| IS No. | Title | IS No. | Title |
|---|---|---|---|
| 4020 (Parts 1 to 16): 1998 | Door shutters - Methods of tests (3rd revision) | 6746: 1994 | Unsaturated polyester resin systems |
| 4043: 1969 | Recommendations for symbolic designation of direction of closing of faces of doors, windows, shutters | 11320: 1997 | Glass fibre rovings for reinforcement of polyester and epoxide resin systems (1st revision) |
| 4021: 1995 | Specification for timber door, window and ventilator frames (3rd revision) | 11551: 1996 | Glass fibre chopped strand mat for reinforcement of polyester resin |
| 4351: 1976 | Specification for steel door frames (1st revision) | 12406: 1988 | Specification for medium density fibre board for general purposes |
| 6523: 1983 | Specification for precast reinforced concrete door and window frames (1st revision) |
| Step | Description |
|---|---|
| 1 | Dry specimen at 105-110°C until constant mass. |
| 2 | Heat in muffle furnace at 575 ± 25°C to burn resin, leaving glass residue. |
| 3 | Cool, weigh, repeat until mass constant within 0.01g. |
| 4 | For filled samples, wash residue, dry, and weigh glass residue after filtration. |
| 5 | Calculate glass content from weight differences (W1, W2, W3). |
If you need specific formulas or test procedures, please specify!
Determination of Glass Content (IS 14856)
| Sample Type | Formula |
|---|---|
| Without filler (B-3a) | [ |
| \text{Glass Content (%)} = \frac{W_3 - W}{W_2 - W} \times 100 | |
| ] | |
| With filler (B-3b) | [ |
| \text{Glass Content (%)} = \frac{W_2 - W_1}{W_2 - W} \times 100 | |
| ] |
Where:
flowchart TD
A[Prepare specimen] --> B[Dry at 105-110°C until constant mass (W2)]
B --> C{Sample type?}
C -->|No filler| D[Heat at 575°C until glass residue white (W3)]
C -->|With filler| E[Heat at 575°C to burn resin, wash residue (W1)]
D --> F[Calculate % glass content: (W3-W)/(W2-W)*100]
E --> F[Calculate
Specimen Requirements (Clause 1.5):
| Property | Formula |
|---|---|
| Tensile Strength (TS) | [ TS = \frac{L_B}{A} ] (MPa) <br> where (L_B) = Load at break (N), (A) = Cross-sectional area (mm²) |
| Bending Strength (S) | [ S = \frac{3PL}{2bd^2} ] (MPa) <br> where (P) = Load at fracture (N), (L) = Support span (m), (b) = Breadth (m), (d) = Thickness (m) |
flowchart LR
A[Specimen Preparation] --> B[Barcol Hardness Test]
B --> C[Indentor Penetration]
C --> D[Read Hardness Value]
D --> E[Average Multiple Readings]
E --> F[Report Barcol Hardness]
For precise testing, follow IS 14856 Annex C Table 3 and Clause 1.5 strictly.
الأسئلة المتكررة
Acceptable Material Composition for GRP Door Shutters (IS 14856)
According to IS 14856:2000, the GRP laminate used in door shutters must meet these minimum material criteria:
| Property | Minimum/Maximum Value | Test Reference |
|---|---|---|
| Fiberglass Content | ≥ 25% (by weight) | Annex B |
| Barcol Hardness | ≥ 30 BHU | Annex C |
| Tensile Strength | ≥ 100 MPa | Annex D |
| Bending Strength | ≥ 120 MPa | Annex E |
| Elastic Modulus (Bend) | ≥ 1500 MPa | Annex F |
| Water Absorption | ≤ 0.5% (by weight) | Annex G |
| Fire Retardancy | Specimen (100 mm length) shall not burn within 60 seconds | Annex H |
These parameters ensure the GRP door shutter's performance and safety as per IS 14856.
Dimensional Tolerances for GRP Panel Door Shutters (IS 14856):
These tolerances ensure the door shutter fits properly and maintains structural integrity.
جارٍ تحميل المخطط…
Summary:
Maintain ±5 mm in width/height, 1 mm max deviation in squareness per 500 mm, and thickness uniformity within 0.8 mm, with a minimum thickness of 5 mm for GRP panel door shutters.
IS 14856 recognizes the following manufacturing processes for glass-reinforced polyester door/window frames:
RTM Process (Resin Transfer Moulding):
Other processes are not explicitly detailed in the provided context, but generally, IS 14856 covers hand lay-up, spray-up, compression moulding, and pultrusion as common manufacturing methods for FRP composites.
| Process Type | Description | Mould Type | Pressure |
|---|---|---|---|
| Resin Injection | Resin injected into fibre preform | Closed mould | Differential |
| Resin Infusion | Resin infused under vacuum | Closed mould | Vacuum |
| Vacuum Press Moulding | Resin and fibres pressed under vacuum pressure | Closed mould | Vacuum + Pressure |
جارٍ تحميل المخطط…
For detailed manufacturing requirements, refer to Clause 3.1.13 and related annexes in IS 14856.
According to IS 14856, GRP door shutters must pass the following mechanical and fire performance tests:
These tests ensure structural integrity, durability, and fire safety of GRP door shutters in buildings.
According to IS 14856, fittings and accessories in door shutter design are accommodated as follows:
Hinges: Each shutter is fixed with three hinges—one at the center, and two at 200 mm from the top and bottom edges. These hinges are mounted where blocks have been pre-provided inside the shutter frame, with the profile depressed to indicate location (Clause 8.2, Fig. 1).
Other Fixtures: All other fittings (locks, handles, etc.) are also installed at locations where blocks have been provided to ensure proper anchorage and strength (Clause 8.3).
Blocks: These internal blocks are sized and positioned as per Fig. 1 in the code, ensuring fittings do not compromise shutter integrity.
| Fitting Type | Location | Provision |
|---|---|---|
| Hinges | Center, 200 mm from top & bottom | Blocks provided with profile depression |
| Other fittings | At block locations | Blocks provided for anchorage |