IS 2110:1980 provides comprehensive guidelines for the in-situ construction of walls in buildings using soil-cement mixtures. It covers soil selection, preparation, mixing with cement, compaction, shuttering, jointing, and finishing techniques to ensure durable and weather-resistant walls. This standard is essential for civil engineers, architects, and construction professionals involved in cost-effective, sustainable building methods using stabilized soil.
نظرة عامة
IS 2110:1980 provides comprehensive guidelines for the in-situ construction of walls in buildings using soil-cement mixtures. It covers soil selection, preparation, mixing with cement, compaction, shuttering, jointing, and finishing techniques to ensure durable and weather-resistant walls. This standard is essential for civil engineers, architects, and construction professionals involved in cost-effective, sustainable building methods using stabilized soil.
الجمهور
المحتويات
الهيكل
Scope (Clause 2.1):
Defines terms related to soil-cement mixtures for construction.
| Characteristic | Requirement |
|---|---|
| Sand content | ≥ 35% by mass |
| Plasticity index (PI) | 8.5% to 10.5% |
| Total soluble salts | ≤ 1% by mass |
| Sodium salts | ≤ 0.1% by mass |
| Liquid limit | ≤ 27% |
flowchart TD
A[Raw Soil] --> B[Check Soil Properties]
B -->|Meets IS 2110 Criteria| C[Mix with Cement & Water]
C --> D[Apply Soil-Cement Mixture]
D --> E[Optional: Apply GOBRI-LEEP Plaster]
E --> F[Final Surface Treatment]
Use IS 2110 as a guide for soil selection, mixture preparation, and finishing to ensure durable soil-cement construction.
IS 2110 - Definitions & Key Specifications
| Characteristic | Requirement |
|---|---|
| Sand content (% by mass) | ≥ 35% |
| Plasticity index (%) | 8.5 to 10.5 |
| Total soluble salts (% by mass) | ≤ 1% |
| Sodium salts (% by mass) | ≤ 0.1% |
| Liquid limit (%) | ≤ 27% |
Summary:
Soil for soil-cement must have minimum 35% sand, plasticity index between 8.5-10.5%, and low soluble salts to avoid durability issues.
flowchart LR
Soil -->|Check Sand Content ≥35%| Suitable
Soil -->|Check Plasticity Index 8.5-10.5%| Suitable
Soil -->|Check Soluble Salts ≤1%| Suitable
Soil -->|Check Sodium Salts ≤0.1%| Suitable
Soil -->|Check Liquid Limit ≤27%| Suitable
Suitable --> Soil-Cement Mix
This ensures compliance with IS 2110 for soil-cement materials.
IS 2110 - Materials Specifications Summary
| Characteristic | Requirement |
|---|---|
| Sand content (% by mass) | Minimum 35% |
| Plasticity index (%) | 8.5 to 10.5 |
| Total soluble salts (%) | Maximum 1% |
| Sodium salts (%) | Maximum 0.1% |
| Liquid limit (%) | Maximum 27% |
flowchart LR
Soil[Raw Soil]
CowDung[Cow Dung (1 part)]
SoilMix[Soil (5 parts)]
Water[Water]
Bitumen[Cut-back Bitumen (5% optional)]
GOBRILEEP[GOBRI-LEEP Paste]
Soil --> SoilMix
CowDung --> GOBRILEEP
SoilMix --> GOBRILEEP
Bitumen --> GOBRILEEP
Water --> GOBRILEEP
This concise summary covers key material specs for soil-cement mixtures per IS 2110.
IS 2110: Preparation of Soil-Cement Mixture — Key Specifications & Formulas
| Characteristic | Requirement |
|---|---|
| Sand content (% by mass) | ≥ 35% |
| Plasticity index (%) | 8.5 to 10.5 |
| Total soluble salts (%) | ≤ 1% |
| Sodium salts (%) | ≤ 0.1% |
| Liquid limit (%) | ≤ 27% |
flowchart TD
A[Select Suitable Soil] --> B[Check Soil Properties]
B --> C{Meets IS 2110 Criteria?}
C -- Yes --> D[Mix Soil with Cement & Water]
C -- No --> E[Reject/Modify Soil]
D --> F[Compaction & Curing]
F --> G[Test Density & Strength]
G --> H{Passes Tests?}
H -- Yes --> I[Use in Construction]
H -- No --> J[Adjust Mix & Retest]
This ensures durable, stable soil-cement suitable for wall construction as per IS 2110.
IS 2110: Construction Procedures for In Situ Soil-Cement Walls
Rammed In Situ Wall Construction (Clause 1.2):
Shuttering Construction (Clause 5.1):
Lifting Process (Clause 5.2.2):
| Material | Proportion (by volume) |
|---|---|
| Clay | 1 part |
| Silt | 1 part |
| Fine Sand | 2 parts |
| Water | As required for workability |
flowchart TD
A[Prepare Soil Mix] --> B[Set Up Shuttering]
B --> C[Place Soil-Cement Mix]
C --> D[Compact Layer (Lift)]
D --> E{Is Wall Height Reached?}
E -- No --> C
E -- Yes --> F[Apply Waterproof Mud Plaster]
Note:
IS 2110: Structural Details & Finishing for Soil-Cement Walls
Horizontal Joints (Clause 6.4.2):
Vertical Joints:
Shuttering (Clause 5.1.1 & 5.2.1):
Plaster Finishing (Clause A-5.1):
| Component | Dimension (mm) | Notes |
|---|---|---|
| Wall Thickness | 300 | Standard thickness |
| MS Angle Iron | 40x40x6 / 50x50x6 | For shuttering support |
| Plank Thickness | As per shuttering design | For vertical and horizontal joints |
graph TD
A[Wall Construction] --> B[Horizontal Joint]
B --> C[Smooth Rammed Surface]
A --> D[Vertical Joint]
D --> E[Tongue & Groove Plank]
A --> F[Shuttering]
F --> G[MS Angle Iron Support]
F --> H[Careful Bolt Removal]
A --> I[Finishing]
I --> J[Gobri-Leep Plaster]
J --> K[Optional Bitumen Addition]
Note: Always refer to IS 2110 figures and clauses for exact dimensions and procedural details.
IS 2110: Quality Control and Testing for Soil-Cement
| Characteristic | Requirement |
|---|---|
| Sand content | ≥ 35% by mass |
| Plasticity index (PI) | 8.5% to 10.5% |
| Total soluble salts | ≤ 1% by mass |
| Sodium salts | ≤ 0.1% by mass |
| Liquid limit | ≤ 27% |
OMC is found from the Proctor test curve where dry density is maximum.
[ \text{OMC} = \text{Moisture content at maximum dry density} ]
flowchart TD
A[Raw Soil] --> B[Check Soil Properties]
B -->|Meets IS 2110| C[Prepare Soil-Cement Mix]
C --> D[Test Samples Periodically]
D --> E{Pass Tests?}
E -->|Yes| F[Use in Construction]
E -->|No| G[Adjust Mix/Reject]
This process ensures soil-cement quality meets IS 2110 standards for durability and strength.
Typical Specification of Waterproof Mud Plaster (IS 2110 - Appendix A)
| Parameter | Specification |
|---|---|
| Soil Sand Content | 45-50% by mass |
| BHUSA (Cut-back Bitumen) | 64 kg/m³ dry soil |
| Plaster Cement-Sand Mix | 1 : 5 |
| Plaster Thickness | ≥ 12 mm (single coat) |
| Reference for Plastering | IS 1661-1972 |
flowchart TD
A[Soil (45-50% sand)] --> B[Add 64 kg BHUSA/m³ dry soil]
B --> C[Mix with water]
C --> D[Allow BHUSA to rot for 1 week]
D --> E[Apply waterproof mud plaster]
E --> F[Apply cement plaster (1:5) ≥ 12 mm thick]
This ensures a durable waterproof mud plaster as per IS 2110 standards.
IS 2110: Details of Shuttering and Joints for In Situ Soil-Cement Walls
Shuttering Thickness: Standard for 300 mm thick walls; modify details for thicker walls (Clause 5.1.1).
Materials:
Shuttering Arrangement:
Construction Joints:
| Component | Dimension (mm) |
|---|---|
| Wall Thickness | 300 (standard) |
| MS Angle at Corner | 50 x 50 x 6 |
| MS Angle (Others) | 40 x 40 x 6 |
flowchart TD
A[Start: Shuttering Setup] --> B[Fix MS Angles & Planks]
B --> C[Assemble Planks with Bolts]
C --> D{Wall Thickness > 300 mm?}
D -- Yes --> E[Modify Shuttering Details]
D -- No --> F[Use Standard Details]
F --> G[Form Vertical Tongue & Groove Joints]
G --> H[Form Horizontal Joints by Smoothing]
H --> I[Complete Shuttering & Casting]
Note: Always ensure planks are aligned plumb and bolts are tightened securely for stability during casting.
الأسئلة المتكررة
According to IS 2110, the suitable soils for soil-cement wall construction are:
Free from deleterious materials such as:
Grading: The soil should have a particle size distribution that requires the least cement admixture for stabilization.
Exclusions:
Additional notes:
| Soil Property | Requirement |
|---|---|
| Organic matter | Must be absent |
| Mica, schists | Must be absent |
| Saline impurities | Must be absent |
| Particle grading | Suitable for minimal cement use |
| Black cotton soil | Not suitable |
This ensures durability and economy in soil-cement wall construction.
Optimum Moisture Content (OMC) Determination & Control as per IS 2110
Determination of OMC:
Control during Construction:
Quality Check:
جارٍ تحميل المخطط…
This ensures optimum compaction and durability of soil-cement structures.
According to IS 2110, the minimum cement content for stabilized soil walls is specified in Clause 4.8.3 and detailed in Clause 4.9:
| Wall Type | Minimum Thickness | Minimum Cement Content (by weight of dry soil) |
|---|---|---|
| Load-bearing walls | ≥ 300 mm | ~5% to 7% |
| Non-load bearing walls | ≥ 200 mm | ~5% to 7% |
Note: Exact cement content should be confirmed by laboratory mix design as per IS 4332.
جارٍ تحميل المخطط…
Design and Removal of Shuttering for Soil-Cement Walls (IS 2110)
Shuttering Design:
Pouring Procedure:
Lintel Support (Clause 6.7.1):
Shuttering Removal:
جارٍ تحميل المخطط…
Summary: Design shuttering per IS 2110 Fig 1, pour soil-cement in 75 mm layers using templates, support lintels with 300 mm bearing, and remove shuttering after adequate curing.
IS 2110 Recommendations for Weather Resistance of Soil-Cement Walls:
| Measure | Purpose |
|---|---|
| Waterproof mud plaster | Surface weather protection |
| Damp-proof course | Moisture barrier |
| Richer cement stabilized soil | Enhanced durability |
| Termite protection | Prevent biological damage |
| Conventional materials below plinth | Moisture resistance at base |
جارٍ تحميل المخطط…
These measures ensure durability and weather resistance per IS 2110.
اسأل AI عن أي بند، متطلب، أو حكم في IS 2110. احصل على ردود فورية مع الاستشهاد بالبند مدعومة بمكتبتنا المفهرسة.