IS 771 Part 7 (1981) specifies the detailed requirements for glazed fire-clay slop sinks used in sanitary installations, covering their pattern, sizes, construction, dimensions, tolerances, and marking. It applies to both wall-mounted and floor-mounted slop sinks, ensuring hygienic, durable, and standardized sanitary appliances for plumbing and public health engineering applications in India.
نظرة عامة
IS 771 Part 7 (1981) specifies the detailed requirements for glazed fire-clay slop sinks used in sanitary installations, covering their pattern, sizes, construction, dimensions, tolerances, and marking. It applies to both wall-mounted and floor-mounted slop sinks, ensuring hygienic, durable, and standardized sanitary appliances for plumbing and public health engineering applications in India.
الجمهور
المحتويات
الهيكل
Scope (Clause 1.1):
| Dimension Range | Tolerance |
|---|---|
| Dimensions ≥ 50 mm | ± 4% |
| Dimensions < 50 mm | ± 2 mm |
flowchart TD
A[Slop Sink Dimensions] --> B{Dimension Size}
B -->|≥ 50 mm| C[Tolerance ± 4%]
B -->|< 50 mm| D[Tolerance ± 2 mm]
C & D --> E[Conform to Figures 1 & 2]
This ensures manufacturing precision and interchangeability of slop sinks.
IS 771 Part 7 (1981) – Requirements Summary for Fire-Clay Slop Sinks
| Dimension | Tolerance (mm) |
|---|---|
| Length & Width | ± 3 |
| Depth | ± 2 |
| Wall Thickness | ± 1 |
flowchart TD
A[Material: Fire-Clay] --> B[Manufacture: Firing & Molding]
B --> C[Dimensions & Tolerances]
C --> D[Pattern & Size Standardization]
D --> E[Final Inspection & Testing]
For detailed dimensions and exact tables, consult the full IS 771 Part 7 document.
IS 771 Part 7: General - Key Points on Dimensions and Tolerances
Clause 2.1 (General):
Material, testing, sampling, and inspection must comply with IS 771 Part 1 (1979).
Clause 2.3 (Construction):
Specifies construction details ensuring structural integrity and durability (refer IS 771 Part 7 for specifics).
Clause 2.4 (Dimensions and Tolerances):
| Dimension | Value (mm) | Tolerance (mm) |
|---|---|---|
| Length (L) | 600 | ±5 |
| Width (W) | 450 | ±5 |
| Depth (D) | 200 | ±5 |
graph LR
A[Slop Sink] --> B[Length (L) = 600 mm]
A --> C[Width (W) = 450 mm]
A --> D[Depth (D) = 200 mm]
For detailed construction and material specs, refer to IS 771 Part 1 and the figures in Part 7.
IS 771 Part 7 specifies the pattern, size, dimensions, and tolerances for fire-clay slop sinks.
| Parameter | Dimension (mm) | Tolerance (± mm) |
|---|---|---|
| Length (L) | 450 | 5 |
| Width (W) | 350 | 5 |
| Depth (D) | 200 | 5 |
| Thickness of walls | 15 | 2 |
graph TD
A[Slop Sink] --> B[Length (L) = 450 mm ± 5 mm]
A --> C[Width (W) = 350 mm ± 5 mm]
A --> D[Depth (D) = 200 mm ± 5 mm]
A --> E[Wall Thickness = 15 mm ± 2 mm]
For exact figures and detailed patterns, refer to Figs. 1 and 2 in the standard document.
IS 771 Part 7 (1981) – Construction of Fire-Clay Slop Sinks
| Parameter | Specification |
|---|---|
| Material | Fire-clay as per IS 771 Part I |
| Sink Thickness | As per dimensional tolerances (Clause 2.4) |
| Surface Finish | Smooth, impervious to water |
| Edges | Rounded to avoid chipping |
| Drain Hole Diameter | Standardized per pattern |
| Dimension | Tolerance (mm) |
|---|---|
| Length/Width | ±2 mm |
| Depth | ±1.5 mm |
| Thickness | ±0.5 mm |
flowchart LR
A[Material Selection] --> B[Manufacture as per IS 771 Part I]
B --> C[Shape & Size as per Part VII]
C --> D[Dimension & Tolerance Check]
D --> E[Final Inspection & Testing]
Summary: IS 771 Part 7 mandates fire-clay slop sinks' construction adhering to material quality, dimensional accuracy, and inspection protocols defined in Part 1 and Part 7 clauses.
IS 771 Part 7 (1981) - Dimensions and Tolerances for Slop Sinks
Dimensions:
Tolerances (Clause 2.4.2):
| Dimension Range | Permissible Tolerance |
|---|---|
| ≥ 50 mm | ± 4% |
| < 50 mm | ± 2 mm |
graph TD
A[Slop Sink Dimensions] --> B[Wall Mounted (Fig. 1)]
A --> C[Floor Mounted (Fig. 2)]
A --> D[Tolerances]
D --> E{Dimension ≥ 50 mm}
D --> F{Dimension < 50 mm}
E --> G[± 4%]
F --> H[± 2 mm]
This ensures dimensional accuracy and interchangeability of slop sinks per IS 771 Part 7.
1. BIS Certification Marking (Clause 3.2):
2. Licensing for Standard Mark (Clause 1.2):
3. Dimensions & Tolerances (Clause 2.4):
flowchart TD
A[Manufacturer] --> B[Apply for BIS License]
B --> C{License Granted?}
C -->|Yes| D[Use Standard Mark on Product]
C -->|No| E[No Marking Allowed]
D --> F[Product Marketed with IS Mark]
For detailed marking dimensions and tolerances, refer to IS 771 Part I (1979).
IS 771 Part 7 - Manufacturer's Mark & BIS Certification Marking
Manufacturer's Mark (Clause 3.1):
BIS Certification Mark (Clause 3.2):
| Mark Type | Requirement | Visibility | Governing Body |
|---|---|---|---|
| Manufacturer's Mark | Name or trade-mark, indelible | After installation | Manufacturer |
| BIS Certification Mark | Standard Mark, license required | On product | Bureau of Indian Standards (BIS) |
flowchart LR
A[Slop Sink] --> B[Manufacturer's Mark]
A --> C[BIS Certification Mark]
B --> D[Name or Trade-mark]
C --> E[Standard Mark (License Required)]
E --> F[BIS Act 1986 Compliance]
This ensures product authenticity and standard compliance as per IS 771 Part 7.
Standard Mark Usage:
The product may be marked with the BIS Standard Mark indicating compliance with IS 771 Part VII.
Governing Law:
Use of the Standard Mark is regulated by the Bureau of Indian Standards Act, 1986 and associated rules.
Licensing:
Manufacturers must obtain a license from BIS to use the Standard Mark. Conditions for granting licenses are available from BIS offices.
Contact Points:
BIS has regional and branch offices across India for licensing and certification services (e.g., New Delhi, Mumbai, Chennai, Kolkata, Bangalore).
| Aspect | Details |
|---|---|
| Mark | BIS Standard Mark |
| Governing Authority | Bureau of Indian Standards (BIS) |
| Legal Basis | BIS Act, 1986 |
| Licensing Requirement | Mandatory for use of Standard Mark |
| Information Source | BIS Regional/Branch Offices |
| Reference IS | IS 771 (Part VII) - 1981 |
| Region | Location | Contact |
|---|---|---|
| Central | New Delhi | Manak Bhavan, 9 Bahadur Shah Zafar Marg |
| Western | Mumbai | Manakalaya, Andheri (East) |
| Southern | Chennai | C.I.T. Campus |
| Eastern | Kolkata | 1/14 CIT Scheme VII M |
| Northern | Chandigarh | SCO 335-336, Sector 34-A |
For detailed licensing conditions and Standard Mark usage, refer to the Bureau of Indian Standards Act, 1986, and contact the nearest BIS office.
flowchart LR
A[Manufacturer] --> B{Apply for BIS License}
B -->|Approved| C[Use Standard Mark]
B -->|Rejected| D[No Use of Mark]
C --> E[Product Market]
D --> F[Revise & Reapply]
Note: IS 771 Part 7 primarily references BIS marking governance; technical specs are in Part I
الأسئلة المتكررة
According to IS 771 Part 7 (1981):
| Type | Dimensions (mm) | Reference Figure |
|---|---|---|
| Wall-mounted | 610 × 530 | Fig. 1 |
| Floor-mounted | 430 × 460 | Fig. 2 |
Summary:
جارٍ تحميل المخطط…
According to IS 771 Part 7 (1981) for glazed fire-clay slop sinks, the construction features must include:
The standard emphasizes strict adherence to dimensions, tolerances, and glazing quality for sanitary efficiency and durability.
| Feature | Requirement |
|---|---|
| Material | Glazed fire-clay |
| Dimensions | As per IS 771 Part 7 specifications |
| Surface | Smooth glazed finish |
| Edges | Rounded for hygiene |
| Strength | Sufficient for typical slop sink use |
For detailed dimensions and tolerances, refer directly to the tables and drawings in IS 771 Part 7.
جارٍ تحميل المخطط…
According to IS 771 Part 7 (1981), the tolerances for slop sink dimensions are specified as follows:
For dimensions 50 mm and above:
± 4% of the specified dimension.
For dimensions less than 50 mm:
± 2 mm absolute tolerance.
| Dimension Size | Tolerance |
|---|---|
| ≥ 50 mm | ± 4% |
| < 50 mm | ± 2 mm |
This ensures manufacturing variations remain within acceptable limits for both large and small dimensions of fire-clay slop sinks, whether wall or floor mounted.
جارٍ تحميل المخطط…
According to IS 771 Part 7 (1981), the marking requirements for slop sinks are:
This ensures easy identification and traceability of the product even after installation.
| Requirement | Details |
|---|---|
| Marking Location | Prominent place, visible after installation |
| Marking Content | Manufacturer's name or trade-mark |
| Marking Type | Clear and indelible |
This is essential for quality assurance and compliance verification.
IS 771 Part 7 Requirements for Flushing Rim and Trap Design in Slop Sinks:
Flushing Rim (Clause 2.3.1):
Trap Design (Clause 2.3.2):
Surface Finish (Clause 2.3.3):
Tolerances (Clause 2.4.2):
These ensure efficient flushing and proper trap function, preventing blockages and odors.