IS 7198:1974 provides a comprehensive code of practice for damp-proofing buildings using bitumen mastic. It covers the application procedures for preventing water penetration and rising damp in both below-ground and above-ground structures, including walls, floors, and foundations. This standard is essential for engineers and construction professionals involved in waterproofing and damp-proofing works using bitumen mastic in reinforced concrete, masonry, and steel structures.
نظرة عامة
IS 7198:1974 provides a comprehensive code of practice for damp-proofing buildings using bitumen mastic. It covers the application procedures for preventing water penetration and rising damp in both below-ground and above-ground structures, including walls, floors, and foundations. This standard is essential for engineers and construction professionals involved in waterproofing and damp-proofing works using bitumen mastic in reinforced concrete, masonry, and steel structures.
الجمهور
المحتويات
الهيكل
Scope (Clause 2.1):
General Considerations (Clause 6.1.1):
Thickness & Laying Method (Clause 8.5):
Mixing Method (Clause 7.1):
| Layer | Thickness/Notes |
|---|---|
| Cement Sand Protective Screed | 5 cm thick |
| Bitumen Mastic Angle Fillet | As per design |
| Lean Base Concrete | As per site requirement |
| Working Platform (Rubble Soling, Rammed Earth, etc.) | Provides stable base |
| Layer/Operation | Specification/Action |
|---|---|
| Protective Screed | 5 cm cement-sand |
| Construction Joints | Warm, clean, pour fresh mastic immediately |
| Mixing | IS 5871-1970 compliant method |
flowchart TD
A[Working Platform] --> B[Lean Base Concrete]
B --> C[Bitumen Mastic Angle Fillet]
C --> D[Cement Sand Protective Screed (5 cm)]
For detailed design and construction, refer to IS 3067-1966, IS 5871-1970, and IS 7198 clauses above.
IS 7198: Key Specifications & Guidelines for Damp-Proofing Design and Construction
flowchart TB
A[Periphery Wall (Hollow)] --> B[Damp-proof Course (Full Thickness)]
B --> C[Bitumen Mastic Layer in Floor]
C --> D[Lean Base Concrete]
D --> E[Floor Concrete]
| Parameter | Specification |
|---|---|
| DPC Location | Full wall thickness (excluding plaster) |
| DPC Height Above Ground | ≥ 150 mm |
| Continuity | Continuous with bitumen mastic in floor |
| Surface Condition | Dry, dewatered during laying |
| Reference Standard | IS 3067-1966 (Bitumen mastic laying) |
This ensures effective damp-proofing integrated with structural elements.
IS 7198 — Materials Key Points
Bitumen Mastic:
Design Information:
Construction Joints (Clause 8.5):
Typical Structural Form (Fig. 4):
| Property | Requirement |
|---|---|
| Penetration (dmm) | 40-90 (at 25°C) |
| Softening Point (°C) | Min. 80 |
| Ductility (cm) | Min. 10 |
| Solubility (%) | Min. 99 |
flowchart LR
A[Existing Mastic Edge] --> B[Warm with Hot Asphalt]
B --> C[Cut & Remove Dust/Dirt]
C --> D[Pour Fresh Mastic Before Cooling]
References:
IS 7198: Allowable Loads Summary
Clause 4.1: When bitumen mastic is not properly compacted to prevent extrusion, the maximum design load should not exceed:
[ \boxed{ 6.5 \text{ kgf/cm}^2 } ]
at maximum atmospheric temperature.
Proper compaction is critical to ensure mastic integrity and allow higher loads.
For design, refer to IS 3067-1966 Clause 2.1 for basic information on load considerations.
| Parameter | Value | Notes |
|---|---|---|
| Max allowable load (improper compaction) | 6.5 kgf/cm² | At max atmospheric temperature |
| Bitumen mastic standard | IS 5871-1970 | For material conformity |
flowchart TD
A[Bitumen Mastic] --> B{Properly Compacted?}
B -- Yes --> C[Allow Higher Loads]
B -- No --> D[Limit Load to 6.5 kgf/cm²]
C --> E[Design According to IS 3067]
D --> E
This ensures safe design respecting IS 7198 provisions.
Key Specifications:
Walls and Floors Above Ground (Clause 6.1.2):
Height Above Ground (Clause 5.2):
Load Limitation (Clause 4.1):
graph TB
A[Periphery Wall (Hollow)] --> B[Damp-proofing across full thickness]
B --> C[Continuous with Bitumen Mastic on Floor]
C --> D[Floor Concrete]
D --> E[Lean Base Concrete]
| Parameter | Specification |
|---|---|
| DPC thickness | Full wall thickness excl. plaster |
| DPC height above ground | ≥ 150 mm |
| Max design load on mastic | ≤ 6.5 kgf/cm² (if not compacted) |
| Continuity | Must link wall and floor DPC |
This ensures effective moisture barrier preventing rising damp and water ingress.
IS 7198: Preparation of Surface and Site for Damp-Proofing
flowchart TB
A[Lean Base Concrete] --> B[Floor Concrete]
B --> C[Bitumen Mastic Layer]
C --> D[Periphery Hollow Wall]
D --> E[Vertical DPC on Inner Surface]
This ensures effective moisture barrier and structural integrity against dampness.
IS 7198 - Method of Mixing and Remelting Bitumen Mastic
| Parameter | Value/Specification |
|---|---|
| Max Temperature | 200°C |
| Heating Method | Mechanical mixer, gradual heat |
| Agitation | Continuous during melting |
| Bitumen Mastic Source | Blocks conforming to IS 5871-1970 |
| Protective Screed | Cement:Sand = 1:4, Thickness = 50 mm |
flowchart TD
A[Bitumen Mastic Blocks] --> B[Stock in layers in mixer]
B --> C[Gradual heating to 200°C]
C --> D[Continuous agitation]
D --> E[Uniform melted bitumen mastic]
This ensures uniform mixing and maintains bitumen mastic quality per IS 7198 requirements.
IS 7198: Thickness & Method of Laying of Bitumen Mastic
| Surface Type | Total Thickness (mm) | Notes |
|---|---|---|
| Horizontal | Typically 10-15 mm | Spread evenly with float |
| Vertical | Typically 8-12 mm | First coat thin, others uniform |
flowchart TD
A[Prepare Surface] --> B[Apply 1st Coat Thinly]
B --> C{Surface Type}
C -->|Horizontal| D[Spread with Float]
C -->|Vertical| E[Plaster with Metal Trowel]
D --> F[Apply 2nd & 3rd Coats with Wooden Float]
E --> F
F --> G[Ensure Uniform Thickness]
G --> H[Apply Next Coat ASAP]
H --> I[Finish with Construction Joints Treatment]
This ensures proper adhesion, uniform thickness, and durability of bitumen mastic as per IS 7198.
IS 7198: Precautions for Internal & External Tanking
| Parameter | External Tanking | Internal Tanking |
|---|---|---|
| Working space outside wall | ≥ 0.6 m | ≥ 0.3 m |
| Base thickness | ≥ 100 mm | Even surface (min 100 mm) |
| Base extension beyond wall | ≥ 150 mm | Not specified |
| Protective screed thickness | 50 mm cement-sand | 50 mm cement-sand (1:4) |
IS 7198 Key Specifications for Joints, Chases, and Angle Fillets
| Feature | Dimension/Specification |
|---|---|
| Joint Staggering | Horizontal ≥ 150 mm, Vertical ≥ 75 mm |
| Chase Size | Minimum 25 mm × 25 mm |
| Angle Fillet Width | Minimum 50 mm, two coats |
flowchart LR
A[Joints] --> B[Staggered: Horizontal ≥150 mm]
A --> C[Staggered: Vertical ≥75 mm]
A --> D[Warm & clean edges before fresh mastic]
E[Chases] --> F[Vertical chase: 25×25 mm min]
G[Angle Fillets] --> H[Min width 50 mm]
G --> I[Apply in two coats]
This ensures durability and proper bonding of bitumen mastic layers as per IS 7198.
Protection of Damp-Proofing Membrane (IS 7198)
Surface Preparation (6.1.1.6):
Walls & Floors Above Ground (6.1.2):
Externally Applied Tanking (6.1.3):
| Element | Dimension |
|---|---|
| Base concrete thickness | 100 mm |
| Base concrete extension | 150 mm beyond wall |
| Cement-sand screed cover | 50 mm |
| Brick wall protection | 10 cm thick |
| Minimum working space | 0.6 m |
graph TD
A[Structural Wall] --> B[Bitumen Mastic Vertical DPC]
B --> C[10 cm Brick Wall Protection]
C --> D[5 cm Cement-Sand Screed]
D --> E[Hard Working Platform (Rubble Soling, Rammed Earth)]
A --> F[100 mm Lean Base Concrete]
F --> G[150 mm Extension for Angle Fillet]
G --> B
Special Treatments Around Openings and Penetrations (IS 7198)
| Component | Thickness/Dimension |
|---|---|
| Base concrete | ≥ 100 mm |
| Base extension beyond wall | ≥ 150 mm |
| Cement-sand screed | 50 mm |
| Brick wall protection | 100 mm |
| Working space outside wall | ≥ 0.6 m |
flowchart TB
A[Wall/Floor with Opening] --> B[Seal opening with bitumen mastic]
B --> C[Wrap pipe/cable tightly]
C --> D[Ensure continuity of tanking]
D --> E[Apply vertical DPC on inner wall]
E --> F[Externally: Provide base concrete ≥100mm]
F --> G[Extend base 150mm beyond wall edge]
G --> H[Apply bitumen mastic angle fillet]
H --> I[Protect with 50mm cement-sand screed]
I --> J[Protect vertical tanking with brick wall]
References:
الأسئلة المتكررة
IS 7198 specifies the use of bitumen mastic as an effective damp-proofing material primarily for:
جارٍ تحميل المخطط…
This ensures effective damp-proofing against ground moisture and hydrostatic pressures.
According to IS 7198 Clause 8.1 and 8.2, the recommended thickness and number of coats for bitumen mastic application are:
| Surface Type | Number of Coats | Total Thickness (mm) | Notes on Application |
|---|---|---|---|
| Walls and floors above ground level | 1 | Minimum 10 | Single coat |
| Vertical surfaces & surfaces steeper than 30° below ground level | 3 | Minimum 20 | First coat thin as adhesive; subsequent coats with wooden float |
| Horizontal & sloping surfaces (≤ 30°) below ground level | 3 | Minimum 30 | Each coat spread evenly with a float |
Additional application tips (Clause 8.2):
This ensures proper waterproofing and durability of the bitumen mastic layer.
Surface Preparation Before Applying Bitumen Mastic (IS 7198)
جارٍ تحميل المخطط…
This ensures a uniform, durable damp-proofing membrane as per IS 7198 requirements.
Precautions for Bitumen Mastic Tanking (IS 7198)
| Surface Type | Number of Coats | Total Thickness |
|---|---|---|
| Above ground walls & floors | 1 | ≥10 mm |
| Vertical & >30° slope below ground | 3 | ≥20 mm |
| Horizontal & ≤30° slope below ground | 3 | ≥30 mm |
جارٍ تحميل المخطط…
Summary: Keep surfaces dry and clean, provide adequate working space, apply correct thickness in specified coats, and protect bitumen mastic immediately with cement-sand screed and physical barriers.
IS 7198 addresses treatment around pipes and service openings in damp-proofing as follows:
جارٍ تحميل المخطط…
This ensures the damp-proofing layer remains continuous and effective around service penetrations.